Cross Flow Closed Circuit Cooling Tower    Cross Flow Closed Circuit Cooling Tower  reaches the ideal cooling effect through the assistance of water and air.Water and air as cooling medium exchange heat with high-temperature product,air inlet and air out from the top of cooling tower.   &n

Featured Products

Cross Flow Closed Circuit Cooling Tower 

   Cross Flow Closed Circuit Cooling Tower  reaches the ideal cooling effect through the assistance of water and air.Water and air as cooling medium exchange heat with high-temperature product,air inlet and air out from the top of cooling tower.

    There are water distrubution system,condensing coils/plates,PVC Filler,Drift eliminator etc. as inside accessories and outside accessories such as pump,air inlet louver,Fan etc. complete the whole Device.

Cross Flow Closed Circuit Cooling Tower
[ Technical Specification ]

The width of cooling tower evaperative condenser is no longer than 2.2m which designed specific to load container for smooth delivery.
 
ModelRated CapacityFanSpraying PumpOperation Weight
Qty.PowerAir VolumeQty.PowerFlow Rate
RTKWm³/hKWm³/hKG
KCN-151511*1.11*1500011*1.11*361280
KCN-252511*1.11*1500011*1.11*361550
KCN-353511*1.11*1500011*1.11*362100
KCN-454522*1.12*1500011*1.11*532300
KCN-555522*1.52*1850011*1.11*532550
KCN-656522*1.52*1850011*1.11*532600
KCN-808022*2.22*2600011*1.11*533400
KCN-909011*5.51*6000011*1.51*703800
KCN-10510511*5.51*6000011*1.51*704200
KCN-12512511*5.51*8000011*1.51*705380
KCN-13513511*7.51*9000011*1.51*705800
KCN-16016011*111*12500011*2.21*1007400
KCN-18018011*111*12500011*2.21*1008200
KCN-20020022*42*5500011*31*1408700
KCN-22022022*5.52*6000011*31*1408900
KCN-24024022*7.52*9000011*41*1809200
KCN-25525822*5.52*8000011*41*1809400
KCN-27527522*7.52*9000011*41*18010500
KCN-29029022*112*12500011*41*18011900
KCN-31531522*112*12500011*41*18013350
KCN-33033022*7.52*9000021*5.51*23315000
Note: the 'Rated Capacity' based on standard condition: water inlet and outlet temp. 37-32degC, wet bulb temp. 28degC.

[ Application ]


CTI Steel Water Evaporative Closed Cooling Tower

[ Key Projects ]

Cross Flow Closed Circuit Cooling Tower

[ Workshop ]

Cross Flow Closed Circuit Cooling Tower

[ our Activities ]


Cross Flow Closed Circuit Cooling Tower
Cross Flow Closed Circuit Cooling Tower

[ Why Choose Casen ]

1, Over 12 Year Experience In Cooling Tower System
2, +1200 Projects Installation Finished Over 35 Countries Worldwide
3, Computer Software Calculation, Performance 110% Reliable
4,Company had passed ISO9001, ISO14001 and OHSAS18001; 21 patents and certificates of CE, PED & SGS.
5, Professional Technical Team, Personal Customization Solution For You.

 Cross Flow Closed Circuit Cooling Tower

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours